NAME
esm – Dell Embedded Server Management
SYNOPSIS
esm0 at mainbus?
DESCRIPTION
The esm driver provides support for the monitoring of the environmental sensors present in a variety of Dell servers. The hardware monitoring is accessed via the hw.sensors sysctl(8) variable.
Devices compatible with the esm driver can provide an arbitrary set of sensors which may include the following types:
| Sensor | Units |
| temperature | uK |
| fan | RPM |
| volts | uVDC |
Sensor data is updated every 10 seconds.
The Embedded Server Management framework has been replaced in more recent Dell systems with the Intelligent Platform Management Interface. Servers using the Intelligent Platform Management Interface may be monitored by the ipmi(4) driver.
WATCHDOG
ESM provides watchdog(4) timer functionality. Once configured, if the watchdog is not reset within a certain period of time, it will timeout and the server will reset. The reset will occur regardless of the recoverability of the hang or crash.
Example of enabling a watchdog:
# sysctl kern.watchdog.period=10
In this case if the watchdog is not reset, it'll reboot the server after roughly 10 seconds.
Example of disabling the watchdog:
# sysctl kern.watchdog.period=0
SEE ALSO
HISTORY
The esm driver first appeared in OpenBSD 3.9.
AUTHORS
The esm driver was written by Jordan Hargrave ⟨[email protected]⟩ and David Gwynne ⟨[email protected]⟩.