# sane-epkowa(5)

SANE backend for EPSON scanners

## NAME

sane-epkowa - SANE backend for EPSON scanners

## DESCRIPTION

The **sane-epkowa** library implements a SANE (Scanner Access Now Easy) backend that provides access to EPSON flatbed scanners.  This backend should be considered **alpha-quality** software!

At present, the following scanners are known to work with this backend:

Model:           \
 japan            other\
 \---------------- -------------------\
 GT-6600U         Perfection 610\
 GT-6700U         Perfection 640U\
 GT-7200U         Perfection 1250\
\
                  Perfection 1250 PHOTO\
 GT-7300U         Perfection 1260\
\
                  Perfection 1260 PHOTO\
 GT-7600S         Perfection 1200S\
 GT-7600U         Perfection 1200U\
 GT-7600UF        Perfection 1200U PHOTO\
 GT-7700U         Perfection 1240U\
 GT-8300UF        Perfection 1660 PHOTO\
 GT-8700          Perfection 1640SU\
 GT-8700F         Perfection 1640SU PHOTO\
 GT-8200U         Perfection 1650\
 GT-8200UF        Perfection 1650 PHOTO\
 GT-9300UF        Perfection 2400 PHOTO\
 GT-9400          Perfection 3170 PHOTO\
 GT-9700F         Perfection 2450 PHOTO\
 GT-9800F         Perfection 3200 PHOTO\
 GT-F500          Perfection 2480 PHOTO\
 GT-F520          Perfection 3490 PHOTO\
 GT-F550          Perfection 2580 PHOTO\
 GT-F570          Perfection 3590 PHOTO\
 GT-F600          Perfection 4180 PHOTO\
 GT-F650          Perfection V100 PHOTO\
 GT-F700          Perfection V350 PHOTO\
 GT-S600          Perfection V10\
 GT-X700          Perfection 4870 PHOTO\
 GT-X750          Perfection 4490 PHOTO\
 GT-X800          Perfection 4990 PHOTO\
 GT-X900          Perfection V700/V750\
 ES-2000          Expression 1600\
 ES-2200          Expression 1680\
 ES-6000          GT-10000\
 ES-6000H         GT-10000+\
 ES-6000HS\
 ES-7000H         GT-15000\
 ES-8500          Expression 1640XL\
 ES-9000H         GT-30000\
 ES-10000G        Expression 10000XL\
 ES-H300          GT-2500\
\
                  Stylus CX2800/CX2900/ME200\
 PX-A550          Stylus CX3500/CX3600\
\
                  Stylus CX3700/CX3800/DX3800\
 PX-A620          Stylus CX3900/DX4000	\
\
                  Stylus CX4100/CX4200/DX4200\
\
                  Stylus CX4500/CX4600\
 PX-A650          Stylus CX4700/CX4800/DX4800\
\
                  Stylus CX4900/CX5000/DX5000\
 CC-600PX         Stylus CX5100/CX5200\
\
                  Stylus CX5300/CX5400\
 PX-A720          Stylus CX5900/CX6000/DX6000\
\
                  Stylus CX6300/CX6400\
\
                  Stylus CX6500/CX6600\
\
                  Stylus CX7700/CX7800\
 PM-A700          Stylus Photo RX420/RX425/RX430\
\
                  Stylus Photo RX500/RX510\
 PM-A750          Stylus Photo RX520/RX530\
 PM-A820          Stylus Photo RX560/RX580/RX590\
 PM-A850          Stylus Photo RX600/RX610\
 PM-A870          Stylus Photo RX620/RX630\
 PM-A890          Stylus Photo RX640/RX650\
 PM-A900          Stylus Photo RX700\
 PM-A920\
 PM-A950\
 PM-A970\
 PM-T990\
 LP-A500          AcuLaser CX11\
 LP-M5500\
 LP-M5600\

For other scanners the software may or may not work.  Please send mail to  sane-devel@lists.alioth.debian.org to report successes or failures.

## OPTIONS

The options the backend supports can either be selected through command line options to programs like scanimage or through GUI elements in xscanimage or xsane.

Valid command line options and their syntax can be listed by using

scanimage --help -d epkowa

Not all devices support all options.

- *Scan Mode*

  The  *--mode* switch selects the basic mode of operation of the scanner valid choices are  *Binary, Gray and Color.* The Binary mode is black and white only, Gray will produce up to 256 levels of gray and Color means 24 bit color mode. Some scanners will internally use 36 bit color,  the external interface however does only support 24 bits.

  The  *--dropout* option determines which color filters are used to scan in Binary mode. Valid choices are None, Red, Green and Blue.

  The *--halftoning* switch selects the mode that is used in Binary mode. Valid options are None,  Halftone A (Hard Tone), Halftone B (Soft Tone), Halftone C (Net Screen),  Dither A (4x4 Bayer), Dither B (4x4 Spiral), Dither C (4x4 Net Screen),  Dither D (8x4 Net Screen), Text Enhanced Technology, Download pattern A,  and Download pattern B.

  The  *--dropout* switch selects the so called dropout color. Valid options are None, Red, Green  and Blue. The default is None. The dropout color is used for  monochrome scanning and selects the color that is not scanned. This can be used to e.g. scan an original with a colored background.

  The *--brightness* switch controls the brightness of the scan. Valid options are the numbers from -3 to  3. The default is 0. The larger the brightness value, the brighter the image gets. If  a user defined table for the gamma correction is selected, the brightness parameter is not available.

  The *--sharpness* switch sets the sharpness of the image data. Valid options are the numbers from -2 to  2, with -2 meaning "Defocus", -1 "Defocus slightly", 0 "Normal", 1 "Sharpen slighly" and 2 "Sharpen".

  The  *--gamma-correction* switch controls the scanner internal gamma correction. Valid options are "Default", "User defined", "High density printing" "Low density printing" and "High contrast printing".

  The  *--color-correction* switch controls the scanner internal color correction function. Valid options are "No  Correction", "Impact-dot printers", "Thermal printers", "Ink-jet printers" and "CRT monitors". The default is "CRT monitors".

  The  *--resolution* switch selects the resolution for a scan. Many EPSON scanners will scan in any resolution between the lowest and highest possible value. The list reported by the scanner can be displayed using the "--help -d epkowa" parameters to scanimage.

  The  *--mirror* option controls the way the image is scanned. By reading the image data from right to left the image is mirored. Valid options are "yes" and "no". The default is "no".

  The  *--speed* option can improve the scan speed in monochrome mode. Valid options are "yes" or "no", the "yes" option will speed up the scan if this option is supported.

  The  *--auto-area-segmentation* switch turns on the automatic area segmentation for monochrome scans. The scanner will try to  determine which areas are text and which contain images. The image areas will be halftoned,  and the text will be impoved. Valid options are "yes" and "no". The default is "yes".

  The  *--gamma-table* parameter can be used to download a user defined gamma table. The options takes 256 values from the range 0-255. In color mode this option equally affects the red, green, and blue channel.

  The  *--red-gamma-table* parameter can be used to download a user defined gamma table for the red channel. The valid options are the same as for --gamma-table.

  The  *--green-gamma-table* parameter can be used to download a user defined gamma table for the green channel. The valid options are the same as for --gamma-table.

  The  *--blue-gamma-table* parameter can be used to download a user defined gamma table for the blue channel. The valid options are the same as for --gamma-table.

  The color correction coefficients *--cct-1 --cct-2 --cct-3 ... --cct-9* will install color correction coefficients for the user defined color correction. Possible  values are in the range -127..127.

  The  *--preview* option requests a preview scan. The frontend software automatically selects a low  resolution. Valid options are "yes" and "no". The default is "no".

  The  *--preview-speed* options will increase the scan speed if this is supported by the scanner. Valid options are "yes" and "no", the default is "no".

  The geometry options *-l -t -x -y* control the scan area: -l sets the top left x coordinate, -t the top left y coordinate,  -x selects the width and -y the height of the scan aea. All parameters are specified in milimeters.

  The *--quick-format* option lets the user select a scan area with predefined sizes. Valid parameters are "CD",  "A5 portrait", "A5 landscape", "Letter", "A4" and "max". The default is "max", which  selects the largest possible area.

  The *--source* option selects the scan source. Valid options depend on the installed options. The default is "Flatbed".

  The  *--auto-eject* option will eject a page after scanning from the document feeder.

## CONFIGURATION FILE

The configuration file /etc/sane.d/epkowa.conf specifies the device(s) that the  backend will use. The current version only supports one scanner per EPSON  backend. Possible connection types are:

- *SCSI*

  This is the default, and if nothing else is specified the backend software will open a given patch as SCSI device. More information about valid syntax for SCSI devices can be found in [sane-scsi(5)](/sane-scsi/5.md).

- *PIP - Parallel Interface*

  The parallel interface can be configured in two ways: An integer number starting at the beginning of a line will be interpreted as the IO address of the parallel port. To make it clearer that a configured IO address is a parallel port the  port address can be preceded by the string "PIO". The PIO connection does not use a special device file in the /dev directory.

- *USB*

  A device file that is preceded by the string "USB" is treated as a scanner  connected via the Universal Serial Bus. The correct special device file has to be created prior to using it with Sane. See the USB documentation for  more information about how to set up the USB subsystem and the required  device files.

## FILES

- */usr/lib/sane/libsane-epkowa.a*

  The static library implementing this backend.

- */usr/lib/sane/libsane-epkowa.so*

  The shared library implementing this backend (present on systems that support dynamic loading).

## ENVIRONMENT

- **SANE\_DEBUG\_EPKOWA**

  If the library was compiled with debug support enabled, this environment variable controls the debug level for this backend.  E.g., a value of 128 requests all debug output to be printed.  Smaller levels reduce verbosity.

- **SANE\_EPSON\_CMD\_LVL**

  This allows to override the function or command level that the backend  uses to communicate with the scanner. The function level a scanner supports is determined during the initialization of the device. If the backend does not recognize the function level reported by the  scanner it will default to function level B5. Valid function levels are A1, A2, B1, B2, B3, B4, B5, B6, B7, B8 and F5. Use this feature only if you know what you are doing!

## SEE ALSO

[sane-scsi(5)](/sane-scsi/5.md), [scanimage(1)](/scanimage/1.md), [xscanimage(1)](/xscanimage/1.md), [xsane(1)](/xsane/1.md), [sane-epson(5)](/sane-epson/5.md)

## BUGS

When used with "scanimage -T" the backend hangs after sucessfully  completing the tests. It is necessary to powercycle the scanner to get the communication between backend and scanner going again.

Sometimes the scanner is not initialized correctly. The problem can be resolved by killing the program and restarting it again.

## UNSUPPORTED DEVICES

The backend may be used with EPSON scanners that are not yet listed  under the list of supported devices. A scanner that is not recognized may default to the function level B3, which means that not all  functions that the scanner may be capable of are accessible.

If the scanner is not even recognized as an EPSON scanner it is  probably because the device name reported by the scanner is not in the correct format. Please send this information to the backend  maintainer (email address is in the AUTHORS file).devices. A scanner that is not recognized may default to the function level B3, which means that not all  functions that the scanner may be capable of are accessible.

If the scanner is not even recognized as an EPSON scanner it is  probably because the device name reported by the scanner is not in the correct format. Please send this information to the backend  maintainer (email address is in the AUTHORS file).

## AUTHOR

EPSON AVASYS Corporation