# otbcli\_SarRadiometricCalibration(1)

OTB SarRadiometricCalibration application

## NAME

otbcli\_SarRadiometricCalibration - OTB SarRadiometricCalibration application

## DESCRIPTION

This is the SarRadiometricCalibration application, version 5.2.0 Perform radiometric calibration of SAR images. Following sensors are supported: TerraSAR-X, Sentinel1 and Radarsat-2.Both Single Look Complex(SLC) and detected products are supported as input.

Complete documentation: http://www.orfeo-toolbox.org/Applications/SarRadiometricCalibration.html

### Parameters:

- **-progress** \<boolean\>

  Report progress

 **-in**       \<string\>         Input Image  (mandatory)\
  **-out**      \<string\> \[pixel\] Output Image  \[pixel=uint8/uint16/int16/uint32/int32/float/double\] (default value is float) (mandatory)

- **-ram**

  \<int32\>          Available RAM (Mb)  (optional, off by default, default value is 128)

- **-noise**

  \<boolean\>        Disable Noise  (optional, off by default)

- **-lut**

  \<string\>         Lookup table sigma /gamma/ beta/ DN. \[sigma/gamma/beta/dn\] (mandatory, default value is sigma)

- **-inxml**

  \<string\>         Load otb application from xml file  (optional, off by default)

## EXAMPLES

otbcli\_SarRadiometricCalibration -in RSAT\_imagery\_HH.tif -out SarRadiometricCalibration.tif

## SEE ALSO

The full documentation for **otbcli\_SarRadiometricCalibration** is maintained as a Texinfo manual.  If the **info** and **otbcli\_SarRadiometricCalibration** programs are properly installed at your site, the command

-

  **info otbcli\_SarRadiometricCalibration**