NAME
opatop
Starts the Fabric Performance Monitor (opatop) Text-based User Interface (TUI) menu to display performance, congestion, and error information about a fabric.
Syntax
opatop [-v] [-q] [-h hfi] [-p port] [--timeout] [-i seconds]
Options
- --help
-
Produces full help text.
- -v/--verbose level
-
Specifies the verbose output level. Value is additive and includes:
- 1
-
Screen
- 4
-
STDERR opatop
- 16
-
STDERR PaClient
- -q/--quiet
-
Disables progress reports.
- -h/--hfi hfi
-
Specifies the HFI, numbered 1..n. Using 0 specifies that the -p port port is a system-wide port number. Default is 0.
- -p/--port port
-
Specifies the port, numbered 1..n. Using 0 specifies the first active port. Default is 0.
- --timeout
-
Specifies the timeout (response wait time) in ms. Default is 1000 ms.
- -i/--interval seconds
-
Interval in seconds at which PA queries are performed to refresh to the latest PA image. Default is 10 seconds.
-h and -p options permit a variety of selections:
- -h 0
-
First active port in system (Default).
- -h 0 -p 0
-
First active port in system.
- -h x
-
First active port on HFI x.
- -h x -p 0
-
First active port on HFI x.
- -h 0 -p y
-
Port y within system (no matter which ports are active).
- -h x -p y
-
HFI x, port y.