name: "opaextractperf2"
section: "8"
platform: "linux"
package: "opa-fastfabric"
version: "10.10.3.0.11-1+b2"
release: "Debian 13 (Trixie)"
platforms: ["linux"]
url: "https://new.carta.tech/opaextractperf2"
---

# opaextractperf2(8)

## NAME

opaextractperf2

Provides a report of all performance counters in a CSV format suitable for importing into a spreadsheet or parsed by other scripts for further analysis. It generates a detailed opareport component summary report and pipes the result to opaxmlextract, extracting element values for NodeDesc, NodeGUID, PortNum, neighbor NodeDesc, neighbor NodeGUID, neighbor PortNum and all the performance counters.

## Syntax

opaextractperf2 \[opareport  *options*\]

## Options

- \--help

  Produces full help text.

- opareport *options*

  The following options are passed to opareport. This subset is considered typical and useful for this command. Do not use the -o/--output report option.

  - \-h/--hfi *hfi*

    Specifies the HFI, numbered 1..n. Using 0 specifies that the -p *port* port is a system-wide port number. Default is 0.

  - \-p/--port *port*

    Specifies the port, numbered 1..n. Using 0 specifies the first active port. Default is 0.

  - \-X/--infile *snapshot\_input*

    Generates a report using the data in the snapshot\_input file. snapshot\_input must have been generated during a previous -o *snapshot* run. When used, the -s, -i, -C, and -a options are ignored. '-' may be used as the snapshot\_input to specify stdin.

  - \-T/--topology *topology\_input*

    Uses topology\_input file to augment and verify fabric information. When used, various reports can be augmented with information not available electronically (such as cable labels). '-' may be used to specify stdin.

  - \-i/--interval *seconds*

    Obtains performance statistics over interval *seconds*. Clears all statistics, waits interval *seconds*, then generates report. Implies -s option.

  - \-b / --begin *date\_time*

    Obtains past performance stats over an interval beginning at *date\_time*. Implies -s option. *date\_time* may be a time entered as HH:MM\[:SS\] or date as mm/dd/YYYY, dd.mm.YYYY, YYYY-mm-dd or date followed by time; for example, "2016-07-04 14:40". Relative times are taken as "x \[second\|minute\|hour\|day\](s) ago.

  - \-e / --end *date\_time*

    Obtains past performance stats over an interval ending at *date\_time*. Implies -s option.

  -

    *date\_time* may be a time entered as HH:MM\[:SS\] or date as mm/dd/YYYY, dd.mm.YYYY, YYYY-mm-dd or date followed by time; for example, "2016-07-04 14:40". Relative times are taken as "x \[second\|minute\|hour\|day\](s) ago.

  - \-C/--clear

    Clears performance statistics for all ports. Only statistics with error thresholds are cleared. A clear occurs after generating the report.

  - \-a/--clearall

    Clears all performance statistics for all ports.

  - \-M/--pmadirect

    Accesses performance statistics using direct PMA.

  - \-A/--allports

    Gets PortInfo for down switch ports. Uses direct SMA to get this data. If used with -M, also gets PMA stats for down switch ports.

  - \-F/--focus *point*

    Specifies the focus area for report. Used for all reports except route to limit scope of report. Refer to *Point Syntax* for details.

## -h and -p options permit a variety of selections:

- \-h 0

  First active port in system (Default).

- \-h 0 -p 0

  First active port in system.

- \-h *x*

  First active port on HFI *x*.

- \-h *x* -p 0

  First active port on HFI *x*.

- \-h 0 -p *y*

  Port *y* within system (no matter which ports are active).

- \-h *x* -p *y*

  HFI *x*, port *y*.

## Point Syntax

- gid:*value*

  *value* is numeric port GID of form: subnet:guid.

- lid:*value*

  *value* is numeric LID.

- lid:value:node

  *value* is numeric LID, selects entire node with given LID.

- lid:*value*:port:*value2*

  *value* is numeric LID of node, *value2* is port number.

- portguid:*value*

  *value* is numeric port GUID.

- nodeguid:*value*

  *value* is numeric node GUID.

- nodeguid:*value1*:port:*value2*

  *value1* is numeric node GUID, *value2* is port number.

- iocguid:*value*

  *value* is numeric IOC GUID.

- iocguid:*value1*:port:*value2*

  *value1* is numeric IOC GUID, *value2* is port number.

- systemguid:*value*

  *value* is numeric system image GUID.

- systemguid:*value1*:port:*value2*

  *value1* is the numeric system image GUID, *value2* is port number.

- ioc:*value*

  *value* is IOC Profile ID String (IOC Name).

- ioc:*value1*:port:*value2*

  *value1* is IOC Profile ID String (IOC Name), *value2* is port number.

- iocpat:*value*

  *value* is glob pattern for IOC Profile ID String (IOC Name).

- iocpat:*value1*:port:*value2*

  *value1* is glob pattern for IOC Profile ID String (IOC Name), *value2* is port number.

- ioctype:*value*

  *value* is IOC type (SRP or OTHER).

- ioctype:*value1*:port:*value2*

  *value1* is IOC type (SRP or OTHER); *value2* is port number.

- node:*value*

  *value* is node description (node name).

- node:*value1*:port:*value2*

  *value1* is node description (node name), *value2* is port number.

- nodepat:*value*

  *value* is glob pattern for node description (node name).

- nodepat:*value1*:port:*value2*

  *value1* is the glob pattern for the node description (node name), *value2* is port number.

- nodedetpat:*value*

  *value* is glob pattern for node details.

- nodedetpat:*value1*:port:*value2*

  *value1* is the glob pattern for the node details, *value2* is port number.

- nodetype:*value*

  *value* is node type (SW or FI).

- nodetype:*value1*:port:*value2*

  *value1* is node type (SW or FI), *value2* is port number.

- rate:*value*

  *value* is string for rate (25g, 50g, 75g, 100g), omits switch mgmt port 0.

- portstate:*value*

  *value* is a string for state (down, init, armed, active, notactive, initarmed).

- portphysstate:*value*

  *value* is a string for PHYs state (polling, disabled, training, linkup, recovery, offline, test)

- mtucap:*value*

  *value* is MTU size (2048, 4096, 8192, 10240), omits switch mgmt port 0.

- labelpat:*value*

  *value* is glob pattern for cable label.

- lengthpat:*value*

  *value* is glob pattern for cable length.

- cabledetpat:*value*

  *value* is glob pattern for cable details.

- cabinflenpat:*value*

  *value* is glob pattern for cable info length.

- cabinfvendnamepat:*value*

  *value* is glob pattern for cable info vendor name.

- cabinfvendpnpat:*value*

  *value* is glob pattern for cable info vendor part number.

- cabinfvendrevpat:*value*

  *value* is glob pattern for cable info vendor revision.

- cabinfvendsnpat:*value*

  *value* is glob pattern for cable info vendor serial number.

- cabinftype:*value*

  *value* is either optical, passive\_copper, active\_copper, or unknown.

- linkdetpat:*value*

  *value* is glob pattern for link details.

- portdetpat:*value*

  *value* is glob pattern for port details.

- sm

  Specifies the master subnet manager (SM).

- smdetpat:*value*

  *value* is glob pattern for SM details.

- route:*point1*:*point2*

  Specifies all ports along the routes between the two given points.

- led:*value*

  *value* is either on or off for LED port beacon.

- linkqual:*value*

  Specifies the ports with a link quality equal to *value*.

- linkqualLE:*value*

  Specifies the ports with a link quality less than or equal to *value*.

- linkqualGE:*value*

  Specifies the ports with a link quality greater than or equal to *value*.

- nodepatfile:*FILENAME*

  Specifies the name of file with the list of nodepats or node descriptions.

- nodepairpatfile:*FILENAME*

  Specifies the name of file with the list of node pairs, separated by a colon.

- ldr

  Specifies the ports with a non-zero link down reason or neighbor link down reason.

- ldr:*value*

  Specifies the ports with a link down reason or neighbor link down reason equal to *value*.

## Example

opaextractperf\
 2 opaextractperf2 -h 1 -p 2

## See Also

*opamergeperf2*