Reference

nvmecontrol(8)

NVM Express control utility

NAME

nvmecontrol – NVM Express control utility

SYNOPSIS

nvmecontrol devlist [-h]

nvmecontrol identify [-v] [-x] [-n nsid] ⟨device-id | namespace-id⟩

nvmecontrol perftest ⟨-n num_threads⟩ ⟨-o read|write⟩ [-p] ⟨-s size_in_bytes⟩ ⟨-t time_in_sec⟩ ⟨namespace-id⟩

nvmecontrol reset ⟨device-id⟩

nvmecontrol logpage ⟨-p page_id⟩ [-x] [-v vendor-string] [-b] [-f LSP] [-i LSI] [-r] ⟨device-id | namespace-id⟩

nvmecontrol ns active ⟨device-id⟩

nvmecontrol ns allocated ⟨device-id⟩

nvmecontrol ns attach ⟨-n nsid⟩ ⟨-c cntid⟩ ⟨device-id⟩

nvmecontrol ns attached ⟨-n nsid⟩ ⟨device-id⟩

nvmecontrol ns controllers ⟨device-id⟩

nvmecontrol ns create ⟨-s nsze⟩ [-c ncap] [-f lbaf] [-m mset] [-n nmic] [-p pi] [-l pil] [-L flbas] [-d dps] ⟨device-id⟩

nvmecontrol ns delete ⟨-n nsid⟩ ⟨device-id⟩

nvmecontrol ns detach ⟨-n nsid⟩ ⟨-c cntid⟩ ⟨device-id⟩

nvmecontrol ns identify [-v] [-x] ⟨-n nsid⟩ ⟨device-id⟩

nvmecontrol nsid ⟨device-id | namespace-id⟩

nvmecontrol resv acquire ⟨-c crkey⟩ [-p prkey] ⟨-t rtype⟩ ⟨-a racqa⟩ ⟨namespace-id⟩

nvmecontrol resv register [-i] [-c crkey] ⟨-k nrkey⟩ ⟨-r rrega⟩ [-p cptpl] ⟨namespace-id⟩

nvmecontrol resv release ⟨-c crkey⟩ ⟨-t rtype⟩ ⟨-a rrela⟩ ⟨namespace-id⟩

nvmecontrol resv report [-e] [-v] [-x] ⟨namespace-id⟩

nvmecontrol firmware [-s slot] [-f path_to_firmware] [-a] ⟨device-id⟩

nvmecontrol format [-n] [-f fmt] [-s sector-size] [-m mset] [-p pi] [-l pil] [-E] [-C] ⟨device-id | namespace-id⟩

nvmecontrol sanitize ⟨-a sanact⟩ [-c owpass] [-d] [-p ovrpat] [-r] [-I] [-U] ⟨device-id⟩

nvmecontrol power [-a apst_state] [-d apst_data] [-l] [-m apst_limit] [-p -power_state] [-w -workload_hint] ⟨device-id | namespace-id⟩

nvmecontrol selftest ⟨-c code⟩ ⟨device-id | namespace-id⟩

nvmecontrol wdc cap-diag [-o -path_template] ⟨device-id⟩

nvmecontrol wdc drive-log [-o -path_template] ⟨device-id⟩

nvmecontrol wdc get-crash-dump [-o -path_template] ⟨device-id⟩

nvmecontrol admin-passthru [args] ⟨device-id⟩

nvmecontrol io-passthru [args] ⟨namespace-id⟩

nvmecontrol discover [-v] [-t transport] [-q HostNQN]

nvmecontrol connect [-FGg] [-c cntl-id] [-i queues] [-k seconds] [-l seconds] [-r seconds] [-t transport] [-q HostNQN] [-Q entries] ⟨address⟩ ⟨SubNQN⟩

nvmecontrol connect-all [-FGg] [-i queues] [-k seconds] [-l seconds] [-r seconds] [-t transport] [-q HostNQN] [-Q entries] ⟨address⟩

nvmecontrol disconnect ⟨device-id | namespace-id | SubNQN⟩

nvmecontrol reconnect ⟨device-id⟩

nvmecontrol reconnect [-FGg] [-i queues] [-k seconds] [-l seconds] [-r seconds] [-t transport] [-q HostNQN] [-Q entries] ⟨device-id⟩ ⟨address⟩

nvmecontrol telemetry-log -O output-file [-d data-area] [-v] ⟨device-id⟩

DESCRIPTION

NVM Express (NVMe) is a storage protocol standard for SSDs and other high-speed storage devices over PCI Express as well as remote storage devices accessed via a network fabric.

devlist

List all NVMe controllers and namespaces along with their device nodes. With the -h argument, use unit suffixes: Byte, Kibibyte, Mebibyte, Gibibyte, Tebibyte and Pebibyte (based on powers of 1024) when showing the disk space. By default, uses Mebibyte.

identify

The identify commands reports information from the drive's IDENTIFY_CONTROLLER if a device-id is specified. It reports IDENTIFY_NAMESPACE data if a namespace-id is specified. When used with disk names, the IDENTIFY_NAMESPACE data is reported, unless the namespace nsid is overridden with the -n flag. Then that namespace's data is reported, if it exists. The command accepts the following parameters:

-n

The namespace ⟨nsid⟩ to use instead of the namespace associated with the device. A nsid of “0” is used to retrieve the IDENTIFY_CONTROLLER data associated with that drive.

logpage

The logpage command knows how to print log pages of various types. It also knows about vendor specific log pages from HGST/WDC, Samsung, Micron and Intel. Note that some vendors use the same log page numbers for different data.

Page 0x01

Drive Error Log

Page 0x02

Health/SMART Data

Page 0x03

Firmware Information

Page 0x04

Changed Namespace List

Page 0x05

Commands Supported and Effects

Page 0x06

Device Self-test

Page 0x80

Reservation Notification

Page 0x81

Sanitize Status

Page 0xc1

Advanced SMART information (WDC/HGST)

Page 0xc1

Read latency stats (Intel)

Page 0xc2

Write latency stats (Intel)

Page 0xc5

Temperature stats (Intel)

Page 0xca

Advanced SMART information (Intel)

Page 0xca

Extended SMART information (Samsung)

Page 0xca

Vendor Unique SMART information (Micron)

Specifying -v help will list all valid vendors and pages. -x will print the page as hex. -b will print the binary data for the page. -s will set Log Specific Field. -i will set Log Specific Identifier. -r will set Retain Asynchronous Event.

ns

Various namespace management commands. If namespace management is supported by device, allow list, create and delete namespaces, list, attach and detach controllers to namespaces. Each NVM device consists of one or more NVM subsystems. Each NVM subsystem has one or more NVM ports. Each NVM port is attached to one or more NVM controllers (though typically 1). Each NVM controller is attached to one or more namespaces.

After a namespace is created, it is considered “allocated”. All namespaces that have not been created are unallocated. An allocated namespace may be active or inactive. An active namespace is attached to the controller and may be interacted with. A namespace can move from active to inactive when detached. An allocated namespace may be deleted to become unallocated. For more details on the nuances of NVM namespaces, please see section 2 Theory of Operation and section 3 NVM Express Architecture of the latest NVM standard.

ns active

Provide a list of active namespace identifiers for the given NVM controller.

ns allocated

Provide a list of allocated namespace identifiers for the given NVM controller.

ns attach

Attach an nsid to a controller. The primary controller is used if one is not specified.

ns attached

Provide a list of controllers attached to a nsid. If only a nvme controller argument is provided, a nsid must also be specified.

ns controllers

Provide a list of all controllers in the NVM subsystem.

ns create

Creates a new namespace.

ns delete

Delete a namespace. It must be currently inactive.

ns detach

Detach a namespace from a controller. The namespace will become inaccessible, but its contents will remain if it is activated again.

ns identify

Print detailed information about the namespace.

nsid

Reports the namespace id and controller device associated with the ⟨namespace-id⟩ or ⟨device-id⟩ argument.

resv acquire

Acquire or preempt namespace reservation, using specified parameters:

-a

Acquire action:

0

Acquire

1

Preempt

2

Preempt and abort

-c

Current reservation key.

-p

Preempt reservation key.

-t

Reservation type:

1

Write Exclusive

2

Exclusive Access

3

Write Exclusive - Registrants Only

4

Exclusive Access - Registrants Only

5

Write Exclusive - All Registrants

6

Exclusive Access - All Registrants

resv register

Register, unregister or replace reservation key, using specified parameters:

-c

Current reservation key.

-k

New reservation key.

-r

Register action:

0

Register

1

Unregister

2

Replace

-i

Ignore Existing Key

-p

Change Persist Through Power Loss State:

0

No change to PTPL state

2

Set PTPL state to 0. Reservations are released and registrants are cleared on a power on.

3

Set PTPL state to 1. Reservations and registrants persist across a power loss.

resv release

Release or clear reservation, using specified parameters:

-c

Current reservation key.

-t

Reservation type.

-a

Release action:

0

Release

1

Clean

resv report

Print reservation status, using specified parameters:

-x

Print reservation status in hex.

-e

Use Extended Data Structure.

format

Format either specified namespace, or all namespaces of specified controller, using specified parameters:

-n, --dry-run

Print the resolved Format NVM command without submitting it to the controller. Identify commands needed to resolve and validate the format parameters are still performed.

-f fmt

The index fmt of the parameters to use. LBA Format #, as specified in the identification of the namespace using “nvmecontrol identify” command with a namespace specified maps this index into these parameters.

-s sector-size

Select the LBA format matching the specified total sector size. The data size is the largest power of two not greater than sector-size, and any remainder is the metadata size. When formatting a namespace, the format with the best relative performance is selected, with the lowest format index used to break ties. When formatting a controller, every active namespace must have exactly one matching format, and that format must have the same index in every namespace. The effective mset, pi, and pil values must also match across all active namespaces. Otherwise, the operation is rejected. This option is mutually exclusive with -f.

-m mset

Metadata Setting. mset

0

do not transfer metadata with LBA information

1

Transfer the metadata as part of the extended LBA information.

-p pi

Protection Information.

0

Protection Information not enabled.

1

Type 1 information protection enabled.

2

Type 2 information protection enabled.

3

Type 3 information protection enabled.

-l pil

Protection Information Location.

0

Transfer the protection metadata as the last N bytes of the transfer.

1

Transfer the protection metadata as the first N bytes of the transfer.

-E

Enables User Data Erase during format. All users data is erased and subsequent reads are indeterminate. The drive may implement this as a cryptographic erase or it may physically erase the underlying media.

-C

Enables Cryptographic Erase during format. All user data is erased cryptographically by deleting the encryption key, rendering it unintelligible.

When formatting specific namespace, existing values are used as defaults. When formatting all namespaces, all parameters should be specified. Some controllers may not support formatting or erasing specific or all namespaces. The nvme(4) driver does not currently support metadata and protection information transfers.

sanitize

Sanitize NVM subsystem of specified controller, using specified parameters:

-a operation

Specify the sanitize operation to perform.

overwrite

Perform an overwrite operation by writing a user supplied data pattern to the device one or more times. The pattern is given by the -p argument. The number of times is given by the -c argument.

block

Perform a block erase operation. All the device's blocks are set to a vendor defined value, typically zero.

crypto

Perform a cryptographic erase operation. The encryption keys are changed to prevent the decryption of the data.

exitfailure

Exits a previously failed sanitize operation. A failed sanitize operation can only be exited if it was run in the unrestricted completion mode, as provided by the -U argument.

1, 2, 3, 4

nvme-cli compatible -a values for “exitfailure”, “block”, “overwrite”, and “crypto” respectively.

-c passes

The number of passes when performing an ‘overwrite’ operation. Valid values are between 1 and 16. The default is 1.

-d

No Deallocate After Sanitize.

-I

When performing an ‘overwrite’ operation, the pattern is inverted between consecutive passes.

-p pattern

32 bits of pattern to use when performing an ‘overwrite’ operation. The pattern is repeated as needed to fill each block.

-U

Perform the sanitize in the unrestricted completion mode. If the operation fails, it can later be exited with the ‘exitfailure’ operation.

-r

Run in “report only” mode. This will report status on a sanitize that is already running on the drive.

power

Manage the power modes of the NVMe controller.

-a state

Enable (1) or disable (0) Autonomous Power State Transition (APST). When enabled, the controller will autonomously switch power states according to configuration data.

-d target:idle[,target:idle ...]

Set the APST data. Each target:idle pair corresponds to a specific available power state starting from the lowest, and defines the target state to transition to, as well as the idle time in milliseconds to wait before that transition. Setting both parameters to zero disables switching from that state.

-l

List all supported power modes. Modes marked with an asterisk (“*”) are non-operational power modes.

-m limit

Configure APST to use all available non-operational power states with total latency below the specified limit (in milliseconds).

-p mode

Set the power mode to mode. This must be a mode listed with the

nvmecontrol power -l

command.

-w hint

Set the workload hint for automatic power mode control.

0

No workload hint is provided.

1

Extended idle period workload. The device is often idle for minutes at a time. A burst of write commands comes in over a period of seconds. Then the device returns to being idle.

2

Heavy sequential writes. A huge number of sequential writes will be submitted, filling the submission queues.

Other

All other values are reserved and have no standard meaning.

Please see the “NVM Subsystem Workloads” section of the relevant NVM Express Base Standard for details.

selftest

Start the specified device self-test:

-c code

Specify the device self-test command code. Common codes are:

0x1

Start a short device self-test operation

0x2

Start an extended device self-test operation

0xe

Start a vendor specific device self-test operation

0xf

Abort the device self-test operation

wdc

The various wdc command retrieve log data from the wdc/hgst drives. The -o flag specifies a path template to use to output the files. Each file takes the path template (which defaults to nothing), appends the drive's serial number and the type of dump it is followed by .bin. These logs must be sent to the vendor for analysis. This tool only provides a way to extract them.

passthru

The “admin-passthru” and “io-passthru” commands send NVMe commands to either the administrative or the data part of the device. These commands are expected to be compatible with nvme-cli. Please see the NVM Express Base Standard for details.

-o --opcode opcode

Opcode to send.

-2 --cdw2 value

32-bit value for CDW2.

-3 --cdw3 value

32-bit value for CDW3.

-4 --cdw10 value

32-bit value for CDW10.

-5 --cdw11 value

32-bit value for CDW11.

-6 --cdw12 value

32-bit value for CDW12.

-7 --cdw13 value

32-bit value for CDW13.

-8 --cdw14 value

32-bit value for CDW14.

-9 --cdw15 value

32-bit value for CDW15.

-l --data-len

Length of the data for I/O (bytes).

-m --metadata-len

Length of the metadata segment for command (bytes). This is ignored and not implemented in nvme(4).

-f --flags

Nvme command flags.

-n --namespace-id

Namespace ID for command (ignored for admin, defaults to device's namespace for io).

-p --prefill

Value to prefill payload with.

-b --raw-binary

Output in binary format (otherwise a hex dump is produced).

-d --dry-run

Do not actually execute the command, but perform sanity checks on it.

-r --read

Command reads data from the device.

-s --show-command

Show all the command values on stdout.

-w --write

Command writes data to the device.

Send arbitrary commands to the device. Can be used to extract vendor specific logs. Transfers to/from the device possible, but limited to MAXPHYS bytes. Commands either read data or write it, but not both. Commands needing metadata are not supported by the nvme(4) drive.

discover

List the remote controllers advertised by a remote Discovery Controller:

-t transport

Transport to use. The default is tcp.

-q HostNQN

NVMe Qualified Name to use for this host. By default an NQN is auto-generated from the current host's UUID.

-v

Display the IDENTIFY_CONTROLLER data for the Discovery Controller.

connect

Establish an association with the I/O controller named SubNQN at address. The address must include a port.

An admin queue pair and one or more I/O queue pairs are created and handed off to the kernel to create a new controller device.

-c cntl-id

Remote controller ID to request:

dynamic

Request a dynamic controller ID for controllers using the dynamic controller model. This is the default.

static

Request a dynamic controller ID for controllers using the static controller model.

number

Request a specific controller ID for controllers using the static controller model.

-F

Request submission queue flow control. By default submission queue flow control is disabled unless the remote controller requires it.

-g

Enable TCP PDU header digests.

-G

Enable TCP PDU data digests.

-i queues

Number of I/O queue pairs to create. The default is 1.

-k seconds

Keep Alive timer duration in seconds. The default is 120.

-l seconds

Controller Loss timer duration in seconds. The default is 600.

This timer starts when an association is lost with a remote I/O controller and is cancelled when a new association is established. If the timer expires, the controller device is deleted. A setting of zero disables this timer.

-r seconds

Reconnect timer duration in seconds. The default is 10.

When an association is lost with a remote I/O controller, the controller device will request reconnection via periodic devctl(4) notifications until either a new association is established or the controller device is deleted. This timer sets the interval between each devctl(4) notification. Note that the first notification is triggered immediately after an association is lost. A setting of zero disables this timer.

-t transport

Transport to use. The default is tcp.

-q HostNQN

NVMe Qualified Name to use for this host. By default an NQN is auto-generated from the current host's UUID.

-Q entries

Number of entries in each I/O queue. The default is the minimum of 128 or the maximum queue size reported by the MQES field of the remote host's CAP property.

connect-all

Query the Discovery Controller at address and establish an association for each advertised I/O controller. The -t flag determines the transport used for the initial association with the Discovery Controller and defaults to tcp. All other flags are used to control properties of each I/O association as described above for the connect command.

disconnect

Delete the controller device associated with a remote I/O controller including any active association and open queues.

reconnect

Reestablish an association for the remote I/O controller associated with device-id. If an address is not provided, the resolved address and settings from the previous association are used to establish a new association. If an address is provided, the supplied address and command line flags are used to establish a new association. In this case, the address must include a port and the flags have the same meaning for the new association as described above for the connect command.

telemetry-log

Extract the telemetry log associated with device-id, using the specified parameters:

-O output-file

Output file for the data. This parameter is mandatory.

-d data-area

The data area is either 1, 2 or 3.

-v

Verbose output reporting progress. This log can be quite large and take minutes to retrieve.

DEVICE NAMES

Where ⟨namespace-id⟩ is required, you can use either the nvmeXnsY device, or the disk device such as ndaZ or nvdZ. The leading /dev/ may be omitted. Where ⟨device-id⟩ is required, you can use either the nvmeX device, or the disk device such as ndaZ or nvdZ. For commands that take an optional ⟨nsid⟩ you can use it to get information on other namespaces, or to query the drive itself. A ⟨nsid⟩ of “0” means query the drive itself.

FABRICS TRANSPORTS

The following NVM Express over Fabrics transports are supported for accessing remote controllers:

tcp

TCP transport

NETWORK ADDRESSES

Network addresses for remote controllers can use one of the following formats:

  • [IPv6 address]:port

  • IPv4 address:port

  • hostname:port

  • [IPv6 address]

  • IPv6 address

  • IPv4 address

  • hostname

If a port is not provided, a default value is used if possible.

EXAMPLES

nvmecontrol devlist

Display a list of NVMe controllers and namespaces along with their device nodes.

nvmecontrol identify nvme0

nvmecontrol identify -n 0 nvd0

Display a human-readable summary of the nvme0 IDENTIFY_CONTROLLER data. In this example, nvd0 is connected to nvme0.

nvmecontrol identify -x -v nvme0ns1

nvmecontrol identify -x -v -n 1 nvme0

Display an hexadecimal dump of the nvme0 IDENTIFY_NAMESPACE data for namespace 1.

nvmecontrol perftest -n 32 -o read -s 512 -t 30 nvme0ns1

Run a performance test on nvme0ns1 using 32 kernel threads for 30 seconds. Each thread will issue a single 512 byte read command. Results are printed to stdout when 30 seconds expires.

nvmecontrol reset nvme0

nvmecontrol reset nda4

Perform a controller-level reset of the nvme0 controller. In this example, nda4 is wired to nvme0.

nvmecontrol logpage -p 1 nvme0

Display a human-readable summary of the nvme0 controller's Error Information Log. Log pages defined by the NVMe specification include Error Information Log (ID=1), SMART/Health Information Log (ID=2), and Firmware Slot Log (ID=3).

nvmecontrol logpage -p 0xc1 -v wdc nvme0

Display a human-readable summary of the nvme0's wdc-specific advanced SMART data.

nvmecontrol logpage -p 1 -x nvme0

Display a hexadecimal dump of the nvme0 controller's Error Information Log.

nvmecontrol logpage -p 0xcb -b nvme0 > /tmp/page-cb.bin

Print the contents of vendor specific page 0xcb as binary data on standard out. Redirect it to a temporary file.

nvmecontrol firmware -s 2 -f /tmp/nvme_firmware nvme0

Download the firmware image contained in "/tmp/nvme_firmware" to slot 2 of the nvme0 controller, but do not activate the image.

nvmecontrol firmware -s 4 -a nvme0

Activate the firmware in slot 4 of the nvme0 controller on the next reset.

nvmecontrol firmware -s 7 -f /tmp/nvme_firmware -a nvme0

Download the firmware image contained in "/tmp/nvme_firmware" to slot 7 of the nvme0 controller and activate it on the next reset.

nvmecontrol power -l nvme0

List all the current power modes.

nvmecontrol power -p 3 nvme0

Set the current power mode.

nvmecontrol power nvme0

Get the current power mode.

nvmecontrol identify -n 0 nda0

Identify the drive data associated with the nda0 device. The corresponding nvmeX devices is used automatically.

nvmecontrol identify nda0

Get the namespace parameters associated with the nda0 device. The corresponding nvmeXnsY device is used automatically.

nvmecontrol format -f 2 -m 0 -p 0 -l 0 -C nvme2

Format all the name spaces on nvme2 using parameters from “LBA Format #2” with no metadata or protection data using cryptographic erase. If the “nvmecontrol identify -n 1 nvme2” command ended with

LBA Format #00: Data Size:   512  Metadata Size:     0  Performance: Good
LBA Format #01: Data Size:   512  Metadata Size:     8  Performance: Good
LBA Format #02: Data Size:  4096  Metadata Size:     0  Performance: Good
LBA Format #03: Data Size:  4096  Metadata Size:     8  Performance: Good
LBA Format #04: Data Size:  4096  Metadata Size:    64  Performance: Good

then this would give a 4k data format for at least namespace 1, with no metadata.

DYNAMIC LOADING

The directories /lib/nvmecontrol and /usr/local/lib/nvmecontrol are scanned for any .so files. These files are loaded. The members of the top linker set are added to the top-level commands. The members of the logpage linker set are added to the logpage parsers.

SEE ALSO

The NVM Express Base Specification, June 10, 2019, https://nvmexpress.org/wp-content/uploads/NVM-Express-1_4-2019.06.10-Ratified.pdf.

HISTORY

The nvmecontrol utility appeared in FreeBSD 9.2.

AUTHORS

nvmecontrol was developed by Intel and originally written by Jim Harris ⟨[email protected]⟩.

This man page was written by Jim Harris ⟨[email protected]⟩.

History

--cdw10 since FreeBSD 12.3-RELEASE; --cdw11 since FreeBSD 12.3-RELEASE; --cdw12 since FreeBSD 12.3-RELEASE; --cdw13 since FreeBSD 12.3-RELEASE; --cdw14 since FreeBSD 12.3-RELEASE; --cdw15 since FreeBSD 12.3-RELEASE; --cdw2 since FreeBSD 12.3-RELEASE; --cdw3 since FreeBSD 12.3-RELEASE; --data-len since FreeBSD 12.3-RELEASE; --dry-run since FreeBSD 12.3-RELEASE; --flags since FreeBSD 12.3-RELEASE; --metadata-len since FreeBSD 12.3-RELEASE; --namespace-id since FreeBSD 12.3-RELEASE; --opcode since FreeBSD 12.3-RELEASE; --prefill since FreeBSD 12.3-RELEASE; --raw-binary since FreeBSD 12.3-RELEASE; --read since FreeBSD 12.3-RELEASE; --show-command since FreeBSD 12.3-RELEASE; --write since FreeBSD 12.3-RELEASE; -2 since FreeBSD 12.3-RELEASE; -3 since FreeBSD 12.3-RELEASE; -4 since FreeBSD 12.3-RELEASE; -5 since FreeBSD 12.3-RELEASE; -6 since FreeBSD 12.3-RELEASE; -7 since FreeBSD 12.3-RELEASE; -8 since FreeBSD 12.3-RELEASE; -9 since FreeBSD 12.3-RELEASE; -C since FreeBSD 14.2-RELEASE; -E since FreeBSD 14.2-RELEASE; -F since FreeBSD 15.0-RELEASE; -G since FreeBSD 15.0-RELEASE; -I since FreeBSD 12.1-RELEASE; -O since FreeBSD 15.0-RELEASE; -Q since FreeBSD 15.0-RELEASE; -U since FreeBSD 12.1-RELEASE; -a since FreeBSD 12.1-RELEASE; -b since FreeBSD 12.3-RELEASE; -c since FreeBSD 12.1-RELEASE; -d since FreeBSD 12.1-RELEASE; -e since FreeBSD 12.1-RELEASE; -f since FreeBSD 12.3-RELEASE; -g since FreeBSD 15.0-RELEASE; -i since FreeBSD 12.1-RELEASE; -k since FreeBSD 12.1-RELEASE; -l since FreeBSD 12.3-RELEASE; -m since FreeBSD 12.3-RELEASE; -n since FreeBSD 12.3-RELEASE; -o since FreeBSD 12.3-RELEASE; -p since FreeBSD 12.1-RELEASE; -q since FreeBSD 15.0-RELEASE; -r since FreeBSD 12.1-RELEASE; -s since FreeBSD 12.3-RELEASE; -t since FreeBSD 12.1-RELEASE; -v since FreeBSD 15.0-RELEASE; -w since FreeBSD 12.3-RELEASE; -x since FreeBSD 12.1-RELEASE.