NAME
nvme-write-zeroes - Send an NVMe write zeroes command, return results
SYNOPSIS
nvme [<global-options>] write-zeroes <device>
[--start-block=<slba> | -s <slba>]
[--block-count=<nlb> | -c <nlb>]
[--ref-tag=<reftag> | -r <reftag>]
[--prinfo=<prinfo> | -p <prinfo>]
[--app-tag-mask=<appmask> | -m <appmask>]
[--app-tag=<apptag> | -a <apptag>] [--deac | -d]
[--limited-retry | -l] [--force-unit-access | -f]
[--namespace-id=<nsid> | -n <nsid>]
[--storage-tag<storage-tag> | -S <storage-tag>]
[--storage-tag-check<storage-tag-check> | -C
<storage-tag-check>]
[--dir-type=<dtype> | -T <dtype>]
[--dir-spec=<dspec> | -D <dspec>]
[--namespace-zeroes | -Z]
DESCRIPTION
The Write Zeroes command is used to set a range of logical blocks to 0.
OPTIONS
- -s <slba>, --start-block=<slba>
-
Start block.
- -c <nlb>, --block-count=<nlb>
-
Number of logical blocks to write zeroes.
- -p <prinfo>, --prinfo=<prinfo>
-
Protection Information field definition.
Bit Description 3 PRACT: Protection Information Action. When set to 1, PI is stripped/inserted on read/write when the block format’s metadata size is 8. When set to 0, metadata is passes. 2:0 PRCHK: Protection Information Check: 2 Set to 1 enables checking the guard tag 1 Set to 1 enables checking the application tag 0 Set to 1 enables checking the reference tag
- -r <reftag>, --ref-tag=<reftag>
-
Optional reftag when used with protection information.
- -m <appmask>, --app-tag-mask=<appmask>
-
Optional application tag mask when used with protection information.
- -a <apptag>, --app-tag=<apptag>
-
Optional application tag when used with protection information.
- -l, --limited-retry
-
Sets the limited retry flag.
- -d, --deac
-
Sets the DEAC bit, requesting controller deallocate the logical blocks.
- -f, --force-unit-access
-
Set the force-unit access flag.
- -n <nsid>, --namespace-id=<nsid>
-
Namespace ID use in the command. The broadcast value 0xffffffff can also be given as all or -1.
- -S <storage-tag>, --storage-tag=<storage-tag>
-
Variable Sized Logical Block Storage Tag(LBST).
- -C <storage-tag-check>, --storage-tag-check=<storage-tag-check>
-
This bit specifies the Storage Tag field shall be checked as part of end-to-end data protection processing.
- -T <dtype>, --dir-type=<dtype>
-
Directive type
- -D <dspec>, --dir-spec=<dspec>
-
Directive specific
- -Z, --namespace-zeroes
-
If set, then the controller clear all logical blocks to zero in the entire namespace.
GLOBAL OPTIONS
The following options are defined at the top-level nvme command and are available to this subcommand:
- --dry-run
-
Print the command that would be executed, but do not actually execute it.
- --no-ioctl-probing
-
Disable probing for 64-bit IOCTL support.
- --no-retries
-
Disable retry logic on transient errors.
- -o <fmt>, --output-format=<fmt>
-
Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.
- --output-format-version=<version>
-
Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.
- --quiet
-
Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.
- --set-options=<key=value>[,<key=value>...]
-
Set libnvme library options for this invocation. Supported keys are force-4k, mi-probe-enabled, test-base-dir and test-sysfs-dir.
- --timeout=<ms>
-
Set the timeout for the command in milliseconds. infinite or -1 waits without a time limit (0xffffffff).
- -v, --verbose
-
Increase the level of detail in the output. May be specified multiple times to further increase verbosity.
These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.
EXAMPLES
No examples yet.
NVME
Part of the nvme-user suite