name: "nvme-registry-list"
section: "1"
platform: "linux"
package: "nvme-cli"
version: "3.2-1"
release: "Arch Linux 2026-11-01"
platforms: ["linux"]
url: "https://new.carta.tech/nvme-registry-list"
---

# nvme-registry-list(1)

List NVMe-oF controller ownership registry entries

## NAME

nvme-registry-list - List NVMe-oF controller ownership registry entries

## SYNOPSIS

```
nvme [<global-options>] registry list
```

## DESCRIPTION

List all live entries in the NVMe-oF controller ownership registry. The registry records which orchestrator (e.g. nvme-stas, nbft) owns each connected NVMe-oF controller. It is stored under /run/nvme/registry/ as one directory per live controller containing one plain-text file per attribute (e.g. /run/nvme/registry/nvme3/owner).

One entry is printed per live registered controller. Controllers with no registry entry (unowned) and non-fabrics (PCIe) controllers (which are never registered) are not shown. Stale entries whose corresponding /dev/nvmeN device node no longer exists are silently skipped.

## OPTIONS

## GLOBAL OPTIONS

The following options are defined at the top-level nvme command and are available to this subcommand:

- \--dry-run

  Print the command that would be executed, but do not actually execute it.

- \--no-ioctl-probing

  Disable probing for 64-bit IOCTL support.

- \--no-retries

  Disable retry logic on transient errors.

- \-o \<fmt\>, --output-format=\<fmt\>

  Set the reporting format to *normal*, *tabular, 'json*, or *binary*. Only one output format may be used at a time.

- \--output-format-version=\<version\>

  Select the output format version. Version *1* uses the original field naming, while version *2* (default) provides more consistent and script-friendly field names. Other versions are rejected.

- \--quiet

  Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.

- \--set-options=\<key=value\>\[,\<key=value\>...\]

  Set libnvme library options for this invocation. Supported keys are *force-4k*, *mi-probe-enabled*, *test-base-dir* and *test-sysfs-dir*.

- \--timeout=\<ms\>

  Set the timeout for the command in milliseconds. *infinite* or *-1* waits without a time limit (0xffffffff).

- \-v, --verbose

  Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

These options can also be set as machine-wide defaults in [nvme-cli.conf(5)](/nvme-cli.conf/5.md). A command-line flag always overrides the file.

## EXAMPLES

• List all owned controllers:

```
# nvme registry list
nvme1
  owner        stas
nvme3
  owner        nbft
```

## SEE ALSO

[nvme-registry-retrieve(1)](/nvme-registry-retrieve/1.md) [nvme-registry-update(1)](/nvme-registry-update/1.md) [nvme-registry-delete(1)](/nvme-registry-delete/1.md) [nvme-disconnect-all(1)](/nvme-disconnect-all/1.md)

## NVME

Part of the nvme-user suite