NAME
nvme-ocp-hardware-component-log - retrieve hardware component log
SYNOPSIS
nvme [<global-options>] ocp hardware-component-log <device>
[--comp-id=<num> | -i <num>]
[--list | -l]
DESCRIPTION
Retrieve hardware component log.
The <device> parameter is mandatory NVMe character device (ex: /dev/nvme0).
This will only work on OCP compliant devices supporting this feature. Results for any other device are undefined.
On success it returns 0, error code otherwise.
OPTIONS
- -i <num>, --comp-id=<num>
-
component identifier
Value Definition 0x0000 Reserved 0x0001 | asic Controller ASIC component 0x0002 | nand NAND Component 0x0003 | dram DRAM Component 0x0004 | pmic PMIC Component 0x0005 | pcb PCB Component 0x0006 | cap capacitor component 0x0007 | reg registor component 0x0008 | case case component 0x0009 | sn Device Serial Number 0x000A | country Country of Origin 0x000B | hw-rev Global Device Hardware Revision 0x000C-0x7FFF Reserved 0x8000 | vendor Vendor Unique Component 0x8001-0xFFFF Vendor Unique Component
- -l, --list
-
list component descriptions
GLOBAL OPTIONS
The following options are defined at the top-level nvme command and are available to this subcommand:
- --dry-run
-
Print the command that would be executed, but do not actually execute it.
- --no-ioctl-probing
-
Disable probing for 64-bit IOCTL support.
- --no-retries
-
Disable retry logic on transient errors.
- -o <fmt>, --output-format=<fmt>
-
Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.
- --output-format-version=<version>
-
Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.
- --quiet
-
Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.
- --set-options=<key=value>[,<key=value>...]
-
Set libnvme library options for this invocation. Supported keys are force-4k, mi-probe-enabled, test-base-dir and test-sysfs-dir.
- --timeout=<ms>
-
Set the timeout for the command in milliseconds. infinite or -1 waits without a time limit (0xffffffff).
- -v, --verbose
-
Increase the level of detail in the output. May be specified multiple times to further increase verbosity.
These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.
EXAMPLES
• Has the program issue a ocp hardware-component-log
# nvme ocp hardware-component-log /dev/nvme0
• Has the program issue a ocp hardware-component-log with asic component list
# nvme ocp hardware-component-log /dev/nvme0 -i asic -l
NVME
Part of the nvme-user suite.