Reference

nvme-intel-smart-log-add(1)

Send NVMe Intel Additional SMART log page request, returns result and log

NAME

nvme-intel-smart-log-add - Send NVMe Intel Additional SMART log page request, returns result and log

SYNOPSIS

nvme [<global-options>] intel smart-log-add <device>
                        [--namespace-id=<nsid> | -n <nsid>]
                        [--raw-binary | -b]
                        [--json | -j]

DESCRIPTION

Retrieves the NVMe Intel Additional SMART log page from the device and provides the returned structure.

The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).

On success, the returned smart log structure may be returned in one of several ways depending on the option flags; the structure may parsed by the program and printed in a readable format or the raw buffer may be printed to stdout for another program to parse.

OPTIONS

-n <nsid>, --namespace-id=<nsid>

Retrieve the Additional SMART log for the given nsid. This is optional and its success may depend on the device’s capabilities to provide this log on a per-namespace basis (see the NVMe Identify Controller for this capability). The default nsid to use is 0xffffffff for the device global SMART log. The broadcast value 0xffffffff can also be given as all or -1.

-b, --raw-binary

Print the raw Intel Additional SMART log buffer to stdout.

-j, --json

Dump output in json format.

GLOBAL OPTIONS

The following options are defined at the top-level nvme command and are available to this subcommand:

--dry-run

Print the command that would be executed, but do not actually execute it.

--no-ioctl-probing

Disable probing for 64-bit IOCTL support.

--no-retries

Disable retry logic on transient errors.

-o <fmt>, --output-format=<fmt>

Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.

--output-format-version=<version>

Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.

--quiet

Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.

--set-options=<key=value>[,<key=value>...]

Set libnvme library options for this invocation. Supported keys are force-4k, mi-probe-enabled, test-base-dir and test-sysfs-dir.

--timeout=<ms>

Set the timeout for the command in milliseconds. infinite or -1 waits without a time limit (0xffffffff).

-v, --verbose

Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.

EXAMPLES

• Print the Intel Additional SMART log page in a human readable format:

# nvme intel smart-log-add /dev/nvme0

• Print the raw Intel Additional SMART log to a file:

# nvme intel smart-log-add /dev/nvme0 --raw-binary > smart_log.raw

It is probably a bad idea to not redirect stdout when using this mode.

NVME

Part of the nvme-user suite

History

--dry-run since Arch Linux 2026-11-01; --json since Debian 10 (Buster); --no-ioctl-probing since Arch Linux 2026-11-01; --no-retries since Arch Linux 2026-11-01; --output-format since Arch Linux 2026-11-01; --output-format-version since Arch Linux 2026-11-01; --quiet since Arch Linux 2026-11-01; --set-options since Arch Linux 2026-11-01; --timeout since Arch Linux 2026-11-01; --verbose since Arch Linux 2026-11-01; -j since Debian 10 (Buster); -o since Arch Linux 2026-11-01; -v since Arch Linux 2026-11-01.