---
name: "nvme-disconnect"
section: "1"
platform: "linux"
package: "nvme-cli"
version: "3.2-1"
release: "Arch Linux 2026-11-01"
platforms: ["linux"]
url: "https://new.carta.tech/nvme-disconnect"
---

# nvme-disconnect(1)

Disconnect one or more Fabrics controller(s).

## NAME

nvme-disconnect - Disconnect one or more Fabrics controller(s).

## SYNOPSIS

```
nvme [<global-options>] disconnect [--device=<device> | -d <device>]
                        [--exclude | -x]
                        [<fabrics-options>]
```

## DESCRIPTION

Disconnects and removes one or more existing NVMe over Fabrics controllers. If the --device option is specified, the controller with that name will be removed. If --nqn is given by itself, every controller connected to the subsystem identified by subnqn will be removed. If --nqn is combined with any of the other fabrics options below (the same ones *nvme connect* accepts, such as --transport, --traddr, --trsvcid, --host-traddr, --host-iface, --hostnqn or --hostid), only the controller(s) matching all of the specified options are removed — useful for disambiguating between multiple controllers connected to the same subsystem. --device cannot be combined with --nqn or any of the other fabrics options.

With --exclude, a matching entry is written to the system-wide NVMe-oF exclusion list before the controller (or subsystem) is torn down, so that a cooperating orchestrator sees the exclusion in place before the removal event fires and does not immediately reconnect. See [nvme-exclusion-add(1)](/nvme-exclusion-add/1.md) and the exclusion list overview for details.

## OPTIONS

- \-d \<device\>, --device \<device\>

  Indicates that the controller with the specified name should be removed. Cannot be combined with --nqn or any of the fabrics options below.

- \-x, --exclude

  Write a matching entry to the *user* exclusion list before disconnecting, so orchestrators do not auto-reconnect the controller. The entry is built from the controller’s transport parameters (or, with a bare --nqn, from the subsystem NQN).

## FABRICS OPTIONS

The following options are common to NVMe over Fabrics commands such as nvme connect:

- \-a \<traddr\>, --traddr=\<traddr\>

  Specify the network address of the controller. For transports using IP addressing (e.g. rdma, tcp), this should be an IP address.

- \--concat

  Enable secure concatenation (TCP).

- \-c \<#\>, --reconnect-delay=\<#\>

  Set the delay in seconds before reconnect is attempted after a connection loss.

- \-C \<secret\>, --kxchap-ctrl-secret=\<secret\>

  Controller authentication secret for bi-directional authentication. If not specified, bi-directional authentication is not attempted.

- \-S \<secret\>, --kxchap-secret=\<secret\>

  Host authentication secret (KX-HMAC-CHAP). Must be provided in ASCII format as defined in the NVMe specification.

- \-C \<secret\>, --dhchap-ctrl-secret=\<secret\>

  Controller authentication secret for bi-directional authentication. If not specified, bi-directional authentication is not attempted. (deprecated, see --kxchap-ctrl-secret)

- \-S \<secret\>, --dhchap-secret=\<secret\>

  Host authentication secret (DH-HMAC-CHAP). Must be provided in ASCII format as defined in the NVMe specification. (deprecated, see --kxchap-secret)

- \--disable-sqflow

  Disable submission queue flow control.

- \-G, --data-digest

  Enable data digest generation/verification (TCP).

- \-D, --duplicate-connect

  Allow duplicate connections to the same subsystem.

- \-g, --hdr-digest

  Enable header digest generation/verification (TCP).

- \-f \<iface\>, --host-iface=\<iface\>

  Specify the network interface to use for the connection.

- \-I \<hostid\>, --hostid=\<hostid\>

  Specify the host UUID.

- \-q \<hostnqn\>, --hostnqn=\<hostnqn\>

  Override the default host NQN.

- \-w \<traddr\>, --host-traddr=\<traddr\>

  Specify the source address on the host side of the connection.

- \-k \<#\>, --keep-alive-tmo=\<#\>

  Set the keep-alive timeout in seconds.

- \--keyring=\<keyring\>

  Keyring to use for TLS key lookup.

- \-n \<subnqn\>, --nqn=\<subnqn\>

  Specify the NVMe subsystem NQN to connect to.

- \-i \<#\>, --nr-io-queues=\<#\>

  Number of I/O queues to create.

- \-P \<#\>, --nr-poll-queues=\<#\>

  Number of polling queues to create.

- \-W \<#\>, --nr-write-queues=\<#\>

  Number of write queues to create.

- \-Q \<#\>, --queue-size=\<#\>

  Queue depth for I/O queues.

- \-l \<#\>, --ctrl-loss-tmo=\<#\>

  Maximum time in seconds to retry reconnect attempts after controller loss.

- \-s \<trsvcid\>, --trsvcid=\<trsvcid\>

  Transport service identifier (e.g. TCP/rdma port). Default is 4420 for RDMA.

- \-T \<#\>, --tos=\<#\>

  Type of service value for the connection (TCP).

- \-t \<trtype\>, --transport=\<trtype\>

  Specify the transport type. Supported values include:

\+

| | |
| --- | --- |
| Value | Description |
| rdma | RDMA (RoCE, iWARP, InfiniBand) |
| tcp | TCP/IP |
| fc | Fibre Channel (**experimental**) |
| loop | Local loopback transport |

- \--tls

  Enable TLS encryption (TCP).

- \--tls-key=\<tls-key\>

  TLS key for the connection. It is recommended to preload keys into the system keyring instead of passing them via the command line.

- \--tls-key-identity=\<identity\>

  Identity associated with the TLS key.

## GLOBAL OPTIONS

The following options are defined at the top-level nvme command and are available to this subcommand:

- \--dry-run

  Print the command that would be executed, but do not actually execute it.

- \--no-ioctl-probing

  Disable probing for 64-bit IOCTL support.

- \--no-retries

  Disable retry logic on transient errors.

- \-o \<fmt\>, --output-format=\<fmt\>

  Set the reporting format to *normal*, *tabular, 'json*, or *binary*. Only one output format may be used at a time.

- \--output-format-version=\<version\>

  Select the output format version. Version *1* uses the original field naming, while version *2* (default) provides more consistent and script-friendly field names. Other versions are rejected.

- \--quiet

  Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.

- \--set-options=\<key=value\>\[,\<key=value\>...\]

  Set libnvme library options for this invocation. Supported keys are *force-4k*, *mi-probe-enabled*, *test-base-dir* and *test-sysfs-dir*.

- \--timeout=\<ms\>

  Set the timeout for the command in milliseconds. *infinite* or *-1* waits without a time limit (0xffffffff).

- \-v, --verbose

  Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

These options can also be set as machine-wide defaults in [nvme-cli.conf(5)](/nvme-cli.conf/5.md). A command-line flag always overrides the file.

## EXAMPLES

• Disconnect all controllers for a subsystem named nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432:

```
# nvme disconnect --nqn=nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432
```

• Disconnect the controller nvme4

```
# nvme disconnect --device=nvme4
```

• Disconnect only the tcp controller for a subsystem at a given traddr, leaving other controllers of the same subsystem (e.g. over a different transport address) connected:

```
# nvme disconnect --nqn=nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432 \
                   --transport=tcp --traddr=192.168.1.100
```

• Disconnect nvme4 and exclude it so orchestrators do not reconnect it:

```
# nvme disconnect --device=nvme4 --exclude
```

## SEE ALSO

[nvme-connect(1)](/nvme-connect/1.md) [nvme-exclusion-add(1)](/nvme-exclusion-add/1.md)

## NVME

Part of the nvme-user suite
