name: "ndctl-monitor"
section: "1"
platform: "linux"
package: "ndctl"
version: "85-1"
release: "Arch Linux 2026-11-01"
platforms: ["linux"]
url: "https://new.carta.tech/ndctl-monitor"
---

# ndctl-monitor(1)

Monitor the smart events of nvdimm objects

## NAME

ndctl-monitor - Monitor the smart events of nvdimm objects

## SYNOPSIS

```
ndctl monitor [<options>]
```

## DESCRIPTION

Ndctl monitor is used for monitoring the smart events of nvdimm objects and dumping the json format notifications to syslog, standard output or a logfile.

The objects to monitor and smart events to notify can be selected by setting options and/or configuration files with .conf suffix under /etc/ndctl.conf.d

Both, the values in configuration file and in options will work. If there is a conflict, the values in options will override the values in the configuration file. Any updated values in the configuration file will take effect only after the monitor process is restarted.

## EXAMPLES

Run a monitor as a daemon to monitor DIMMs on bus "nfit\_test.1"

```
ndctl monitor --bus=nfit_test.1 --daemon
```

Run a monitor as a one-shot command and output the notifications to /var/log/ndctl.log

```
ndctl monitor --log=/var/log/ndctl.log
```

Run a monitor daemon as a system service

```
systemctl start ndctl-monitor.service
```

## OPTIONS

\-b, --bus=

A bus id number, or a provider string (e.g. "ACPI.NFIT"). Restrict the operation to the specified bus(es). The keyword *all* can be specified to indicate the lack of any restriction, however this is the same as not supplying a --bus option at all.

\-d, --dimm=

A *nmemX* device name, or a dimm id number. Restrict the operation to the specified dimm(s). The keyword *all* can be specified to indicate the lack of any restriction, however this is the same as not supplying a --dimm option at all.

\-r, --region=

A *regionX* device name, or a region id number. Restrict the operation to the specified region(s). The keyword *all* can be specified to indicate the lack of any restriction, however this is the same as not supplying a --region option at all.

\-n, --namespace=

A *namespaceX.Y* device name, or namespace region plus id tuple *X.Y*.

\-l, --log=

Send log messages to the specified destination.

• "\<file\>": Send log messages to specified \<file\>. When fopen() is not able to open \<file\>, log messages will be forwarded to syslog.

• "syslog": Send messages to syslog.

• "standard": Send messages to standard output.

The default log destination is *syslog* if "--daemon" is specified, otherwise *standard*. Note that standard and relative path for \<file\> will not work if "--daemon" is specified.

\-c, --config-file=

Provide the config file(s) to use. This overrides the default config typically found in /etc/ndctl.conf.d

- \--daemon

  Run a monitor as a daemon.

\-D, --dimm-event=

Name of an smart health event from the following:

• "dimm-spares-remaining": Spare Blocks Remaining value has gone below the pre-programmed threshold.

• "dimm-media-temperature": NVDIMM Media temperature value has gone above the pre-programmed threshold.

• "dimm-controller-temperature": NVDIMM Controller temperature value has gone above the pre-programmed threshold.

• "dimm-health-state": NVDIMM Normal Health Status has changed

• "dimm-unclean-shutdown": NVDIMM Last Shutdown Status was a unclean shutdown.

The monitor will attempt to enable the alarm control bits for all specified events.

\-p, --poll=

Poll and report status/event every \<n\> seconds.

- \-u, --human

  Output monitor notification as human friendly json format instead of the default machine friendly json format.

- \-v, --verbose

  Emit extra debug messages to log.

## COPYRIGHT

Copyright (c) 2018, FUJITSU LIMITED. License GPLv2: GNU GPL version 2  \<http://gnu.org/licenses/gpl.html\>. This is free software: you are free to change and redistribute it. There is NO WARRANTY, to the extent permitted by law.

## SEE ALSO

[ndctl-list(1)](/ndctl-list/1.md), [ndctl-inject-smart(1)](/ndctl-inject-smart/1.md)