lccnorm transforms LC-style call numbers into a form that may be used in a straight ASCII sort.
By default, each line of input is assumed to consist of a number of tab-delimited fields, of which the first contains an LC-style call number or class.
If no file is specified, or if the file name "-" is specified, standard input will be processed.
Normalization of call number ranges is a special challenge, because ranges are not normally specified using the exact endpoint. Consider the range "B708-B713"; while "B708" does indicate the beginning point -- a no call number that comes before B 708 can fall within the range -- the end point is only a guide, not a strict limit, since the intent is that call numbers such as "B 713 .H94" and "B 713 .W55 L86" do fall within the range. Unfortunately, ranges are often specified ambiguously; for example, the call number "B 713.14 G92" might or might not be considered to fall within this range.
Options
-
-d, --delimiter string -
Specify a string other than a single tab (ASCII character 9) to delimit the fields in a line of input. This also provides the default for joining fields in the output; see option
-jbelow.
-
-f, --field range -
The call number (or range) is found in the given range of fields. Fields are 1-based (the first field is field 1, not field 0) and are separated by a single tab character (unless option
-dis used to specify an alternate delimiter).When parsing call numbers (not ranges), all fields are concatenated using a single space to form the call number that will be normalized.
When parsing ranges, there are four possibilities:
- 1 field
-
The field contains a range in the form prefix (e.g.,
"J80"), closed range (e.g.,"ML566-566.6"or"ML566-ML566.6") or half-open range (e.g.,"KME451<KME500").
- 2 fields
-
The first field is the beginning of the (closed) range, and the second is the end.
- 3 fields
-
The first field is a prefix common to both the beginning and end of the range, and the second and third fields are the remainders.
- 4 fields
-
The first and third fields together are the beginning of the range, and the second and fourth are the end.
For example, the following all produce identical output:
$ echo 'PL4501-4509' | lccnorm -d: -f1$ echo 'PL4501:PL4509' | lccnorm -d: -f1-2$ echo 'PL:4501:4509' | lccnorm -d: -f1-3$ echo 'PL:4501:PL:4509' | lccnorm -d: -f1-4
-
-j, --join string -
Specify a character to use when joining fields for output. The default is to use the same string specified in option
-d, or a single tab if-dwas not given.
-
-c -
Don't delete the input fields from which call numbers (or ranges) were obtained. Either the
-band-eoption must be provided to specify where the normalized string is to be placed.
-
-b, --begin -
Place normalized strings at the beginning of output lines.
-
-e, --end -
Place normalized strings at the end of output lines.
-
-D, --die-on-error -
Exit with a non-zero status as soon as an unnormalizable input is encountered. The default is to issue a warning and normalize to the empty string.
-
-v, --verbose -
Be verbose. This currently has no effect unless used with the
-Vor--versionoption.
-
-h, --help -
Print help information and exit.
-
-V, --version -
Print the version number and exit. If the
-vor--verboseoption is specified, print out additional information.
-
-M, --manual -
View the manual page for
lccnorm.
-
-L, --license -
View the license under which
lccnormis distributed.
Releases