# egctl(1)

EnerGenie EG-PMS-LAN control utility

## NAME

egctl - EnerGenie EG-PMS-LAN control utility

## SYNOPSIS

**egctl** *NAME* \[*S1 S2 S3 S4*\]

## DESCRIPTION

**egctl** is a program to control the state of EnerGenie Programmable surge protector with LAN interface. It uses native EG-PMS-LAN data exchange protocol version 2.0 or 2.1, not HTTP. When executed with the only argument it dumps the state of the specified device. If all five arguments are specified, it changes the state of the device and dumps the new state.\

## OPTIONS

- *NAME*

  The name of the device to control (as it is specified in the configuration file). This name has no relation to the IP address or the domain name.

- *Sn*

  The action to perform on *n*-th socket. Possible values are: **on**, **off**, **toggle** and **left**.

## CONFIGURATION

Configuration file is a table of devices. Each device is described on a separate line; fields on each line are separated by tabs or spaces. Lines starting with '#' are comments, blank lines are ignored.

- **The first field**

  Name of device. It is a string that will be used to address the device in the utility commands. It is not necessary to be the same as **Server name** in the web interface.

- **The second field**

  Protocol. Supported protocols are: **pms20** and **pms21.**

- **The third field**

  IP address of device.

- **The fourth field**

  TCP port of device. (**Power Manager client port** in the web interface).

- **The fifth field**

  Password.

## SUPPORTED DEVICES

| | |
| --- | --- |
| **Device** | **Protocol** |
|
| EG-PMS2-LAN | pms21 |

## EXAMPLES

Suppose a user has two EG-PMS-LAN devices configured as follows:

-

  1\. 192.168.0.10, port 5000, password hackme\
   2\. 192.168.10.10, port 5001, password hackmesoftly

In order to control them using the utility the user needs to create a configuration file like the following:

-

  eg1 pms20 192.168.0.10  5000 hackme\
   eg2 pms20 192.168.10.10 5001 hackmesoftly

Now she can get the status of the devices with commands

-

  **egctl eg1**\
   **egctl eg2**

and switch the state of the AC power sockets with a command like

-

  **egctl eg1 on left left off**

## FILES

- *~/.egtab*

  user's configuration file

- */etc/egtab*

  system-wide configuration file

## BUGS

This program cannot modify the internal schedule of the device.