NAME
dlt-logstorage-ctrl - Trigger DLT Daemon to start/stop using an offline logstorage device
SYNOPSIS
dlt-logstorage-ctrl [-h] [-c ctype] [-p path] [-e ecu] [-p<prop>] [-t timeout] [-v]
DESCRIPTION
Send a trigger to DLT Daemon to connect/disconnect a certain offline logstorage device
OPTIONS
- -h
-
Display a short help text.
- -c
-
Specify connection type: connect = 1, disconnect = 0.
- -d
-
Run as daemon: prop = use proprietary handler
- -p
-
Mount point path.
- -e
-
Specify the ECU ID. Default is: ECU1.
- -t
-
Specify connection timeout. Default is: 10s.
- -S
-
Send message with serial header (Default: Without serial header)
- -R
-
Enable resync serial header
EXAMPLES
Activate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 1 -p /mnt/dltlog
Deactivate the offline logstorage device mounted on /mnt/dltlog dlt-logstorage-ctrl -c 0 -p /mnt/dltlog
Run logstorage control application as daemon listen to udev events dlt-logstorage-ctrl -d
EXIT STATUS
Non zero is returned in case of failure.
AUTHOR
Christoph Lipka (clipka (at) jp.adit-jv (dot) com), Syed Hameed (shameed (at) jp.adit-jv (dot) com)
COPYRIGHT
Copyright (C) 2015 Advanced Driver Information Technology, Bosch and DENSO. License MPL-2.0: Mozilla Public License version 2.0 ⟨http://mozilla.org/MPL/2.0/⟩\c .
BUGS
See Github issue: ⟨https://github.com/COVESA/dlt-daemon/issues⟩\c