# citron(4x)

Citron Infrared Touch Driver (CiTouch)

## NAME

citron - Citron Infrared Touch Driver (CiTouch)

## SYNOPSIS

```
Section "InputDevice"
  Identifier "idevname"
  Driver "citron"
  Option "Device"   "devpath"
  ...
EndSection
```

## DESCRIPTION

**citron** is a XFree86 input driver for  *Citron Infrared Touch* devices.

The **citron** driver acts as a pointer input device, and may be used as the X server's core pointer. It is connected via a "RS232" with the host.

## SUPPORTED HARDWARE

At the moment the following touches are supported. They are also available as  *ZPress* touches.

**IRT6I5-V2.x**\
  6\.5 inch Infrared Touch

**IRT10I4-V4.x**\
  10\.4 inch Infrared Touch

**IRT12I1-V2.x**\
  12\.1 inch Infrared Touch

**IRT15I1-V1.x**\
  15\.1 inch Infrared Touch

## CONFIGURATION DETAILS

Please refer to [XF86Config-4(5x)](/XF86Config-4/5x.md) for general configuration details and for options that can be used with all input drivers.  This section only covers configuration details specific to this driver. For better understanding please read also the  **CTS** and various **IRT** manuals which are available in "pdf" format from Citron web page  **www.citron.de** or directly from Citron.

The following driver **Options** are supported:

- **Option "Device" "***devpath***"**

  Specify the device path for the citron touch.  Valid devices are:

/dev/ttyS0, /dev/ttyS1, ...

This option is mandatory.

It's important to specify the right device Note: com1 -\> /dev/ttyS0, com2 -\> /dev/ttyS1, ...

- **Option "ScreenNumber" "***screennumber***"**

  sets the *screennumber* for the  **citron** InputDevice.

*Default:* ScreenNumber: "0"

- **Option "MinX" "***value***"**

  - **Option "MinY" "***value***"**

  These are the minimum X and Y values for the  **citron** input device.

Note: MinX, MinY must be less than MaxX, MaxY.

*Range:* "0" - "65535"

*Default:* MinX: "0"  MinY: "0"

- **Option "MaxX" "***value***"**

  - **Option "MaxY" "***value***"**

  These are the maximum X and Y values for the  **citron** input device.

Note: MaxX, MaxY must be greater than MinX, MinY.

*Range:* "0" - "65535"

*Default:* MaxX: "65535"  MaxY: "65535"

- **Option "ButtonNumber" "***value***"**

  This value is responsible for the  *button number* that is returned within the xf86PostButton event message

*Range:* "0" - "255"

*Default:* "1"

- **Option "ButtonThreshold" "***value***"**

  This value is responsible for the  *button threshold.* It changes the pressure sensitivity of the touch. A higher number corresponds to a higher pressure.

Note: This feature is only available with pressure sensitive hardware.

*Range:* "0" - "255"

*Default:* "20"

- **Sleep-Mode**

  If the IRT is in  *Doze-Mode* and Touch Zone is not interrupted for another  certain span of time, the so-called *Sleep-Mode* is activated. The  *Sleep-Mode* decreases the scan rate of the beams even further than the  *Doze-Mode* does (see below). This way the life expectancy of the beams is  prolonged and the power consumption of the IRT is reduced.  As soon as an interruption of the Touch Zone is detected, the  *Sleep-Mode* is deactivated and the Touch Zone will again be scanned with  the maximum speed. With the Sleep-Mode activated,  depending on the set scan rate the IRT's response time can be considerably longer as in normal operation. If, for example,  a scan rate of 500 ms / scan is set, it may last up to a half  of a second until the IRT detects the interruption and deactivates  the  *Sleep-Mode.*

- **Option "SleepMode" "***mode***"**

  This value is responsible for the  *sleep-mode* of the touch.

  Determines the behaviour of the Sleep-Mode.

  **0x00**\
    No message at either activation or deactivation

  **0x01**\
    Message at activation

  **0x02**\
    Message at deactivation

  **0x03**\
    Message at activation and deactivation

  **0x10** GP\_OUT output set according to the Sleep-Mode status

  *Values:* "0" "1" "2" "3" "16"

  *Default:* "0"

- **Option "SleepTime" "***time***"**

  This value is responsible for the  *sleep-time* of the touch. It is the activation time in seconds  ("0" = immediately activated, "65535" = always deactivated).

  *Range:* "0" - "65535" \[s\]

  *Default:* "65535" =\> deactivated

- **Option "SleepScan" "***scan***"**

  This value is responsible for the  *scan-time* of the touch. This is the time interval between two scan operations while in Sleep-Mode. The time interval is set in steps of milliseconds.

  *Range:* "0" - "65535" \[ms\]

  *Default:* "500"

- **Option "PWMActive" "***value***"**

  This value determines the mark-to-space ratio of the  *PWM* output while in normal operation (sleep-mode not active). Higher values result in longer pulse widths. This output  signal can be used in conjunction with the  *Citron AWBI* to do backlight-dimming via the touch.

  *Range:* "0" - "255"

  *Default:* "255" (max. brightness)

- **Option "PWMSleep" "***value***"**

  This value determines the mark-to-space ratio of the  *PWM* output while in sleep-mode (-\> *SleepMode, SleepScan, SleepTime* ) operation (sleep-mode active). Higher values result in longer pulse widths.

  *Range:* "0" - "255"

  *Default:* "255" (max. brightness)

- **Option "PWMFreq" "***value***"**

  This value determines the *PWM* frequency in Hertz.

  *Range:* "39" - "9803"

  *Default:* "9803" (max. frequency)

- **Option "ClickMode" "***mode***"**

  With mode one can select between 5  *ClickModes*

  **"1"** = ClickMode Enter

  With this mode every interruption of the infrared beams will activate a ButtonPress event and after the interruption a ButtonRelease event will be sent.

  **"2"** = ClickMode Dual

  With this mode every interruption will sent a Proximity event and every second interruption a ButtonPress event. With the release of the interruption (while one interruption is still active) a ButtonRelease event will be sent.

  **"3"** = ClickMode Dual Exit

  With this mode every interruption will sent a ProximityIn event and every second interruption a ButtonPress event. With the release of the interruption (while one interruption is still active) no ButtonRelease event will be sent. Only if all interruptions are released a ButtonRelease followed by a ProximityOut event will be sent.

  **"4"** = ClickMode ZPress

  With this mode every interruption will sent a ProximityIn event. Only if a certain pressure is exceeded a ButtonPress event will occur. If the pressure falls below a certain limit a ButtonRelease event will be sent. After also the interruption is released a ProximityOut event is generated.

  **"5"** = ClickMode ZPress Exit

  This mode is similar to "Clickmode Dual Exit".  The first interruption of the beams will sent a ProximityIn event. Only if a certain pressure is exceeded a ButtonPress event will occur. If the pressure falls below a certain limit no ButtonRelease event will be sent. After the interruption is also released a ButtonRelease followed by a ProximityOut event is generated.

  *Range:* "1" - "5"

  *Default:* "1" (ClickMode Enter)

- **Option "Origin" "***value***"**

  This value sets the coordinates origin to one of the four corners of  the screen. The following values are accepted: "0" TOPLEFT: Origin set to the left-hand side top corner. "1" TOPRIGHT: Origin set to the right-hand side top corner. "2" BOTTOMRIGHT: Origin set to the right-hand side bottom corner. "3" BOTTOMLEFT: Origin set to the left-hand side bottom corner.

  *Range:* "0" - "3"

  *Default:* "0" (TOPLEFT)

- **Doze-Mode**

  If for a certain span of time the Touch Zone is not interrupted, the so-called Doze-Mode is automatically activated. The activated  Doze-Mode slightly decreases the scan rate of the beams. This way  the power consumption of the IRT is reduced. As soon as an  interruption of the Touch Zone is detected, the Doze-Mode is deactivated and the Touch Zone will again be scanned with  the maximum speed.

- **Option "DozeMode" "***mode***"**

  This value is responsible for the  *doze-mode* of the touch.

  Determines the behaviour of the Doze-Mode.

  **0x00** No message at either activation or deactivation

  **0x01** Message at activation

  **0x02** Message at deactivation

  **0x03** Message at activation and deactivation

  **0x10** GP\_OUT output set according to the Doze-Mode status

  If the GP\_OUT output is already controlled by the  *Sleep-Mode* it is no longer available as an output port anymore.

  *Values:* "0" "1" "2" "3" "16"

  *Default:* "0"

- **Option "DozeTime" "***time***"**

  This value is responsible for the  *doze-time* of the touch. It is the activation time in seconds  ("0" = immediately activated, "65535" = always deactivated).

  *Range:* "0" - "65535" \[s\]

  *Default:* "65535" =\> deactivated

- **Option "DozeScan" "***scan***"**

  This value is responsible for the  *scan-time* of the touch. This is the time interval between two scan operations while in Doze-Mode. The time interval is set in steps of milliseconds.

  *Range:* "0" - "65535" \[ms\]

  *Default:* "500"

- **Option "DeltaX" "***value***"**

  This value determines a virtual area at the left and right side of the current cursor position where the cursor didn't move. Within this area no "MotionNotify" event will be sent.

  *Range:* "0" - "255"

  *Default:* "0" (no deltaX)

- **Option "DeltaY" "***value***"**

  This value determines a virtual area at the top and bottom of the current cursor position where the cursor didn't move. Within this area no "MotionNotify" event will be sent.

  *Range:* "0" - "255"

  *Default:* "0" (no deltaY)

- **Option "Beep" "***value***"**

  This value determines if a "ButtonPress" and/or a "ButtonRelease" event should sound the buzzer. "0" deactivates the buzzer while every other value will activate it.

  *Range:* "0" - "1"

  *Default:* "0" (deactivated)

- **Option "PressVol" "***value***"**

  This value determines the volume of the buzzer (0-100%) when a "ButtonPress" event is sent.

  *Range:* "0" - "100"

  *Default:* "100"

- **Option "PressPitch" "***value***"**

  This value determines the pitch of the tone when a "ButtonPress" event is sent.

  *Range:* "0" - "3000"

  *Default:* "880"

- **Option "PressDur" "***value***"**

  This value determines the duration of the tone in ms when a "ButtonPress" event is sent.

  *Range:* "0" - "255"

  *Default:* "15"

- **Option "ReleaseVol" "***value***"**

  This value determines the volume of the buzzer (0-100%) when a "ButtonRelease" event is sent.

  *Range:* "0" - "100"

  *Default:* "100"

- **Option "ReleasePitch" "***value***"**

  This value determines the pitch of the tone when when a "ButtonRelease" event is sent.

  *Range:* "0" - "3000"

  *Default:* "1200"

- **Option "ReleseDur" "***value***"**

  This value determines the duration of the tone in ms when when a "ButtonRelease" event is sent.

  *Range:* "0" - "255"

  *Default:* "10"

- **Option "BeamTimeout" "***value***"**

  Determines the time span in seconds, that has to elapse before a beam is  considered defective, blanked-out and excluded from the coordinates  evaluation.

  *Range:* "0" - "65535"

  *Default:* "30" (30 seconds)

- **Option "TouchTime" "***value***"**

  Determines the minimum time span in steps of 10ms for a valid  interruption. In order for an interruption to be reported to the host computer as valid, it needs to remain at  the same spot for at least the time span declared here.

  *Range:* "0" - "255"

  *Default:* "0" (=6,5 ms)

- **Option "EnterCount" "***count***"**

  Number of skipped "enter reports". Reports are sent approx.  every 20ms.

  *Range:* "0" - "31"

  *Default:* "3" (3 skipped messages = 60ms)

- **Option "ZEnterCount" "***count***"**

  Number of skipped "enter reports" while in pressure sensitive mode. Reports are sent approx. every 20ms.

  *Range:* "0" - "31"

  *Default:* "1" (1 skipped messages = 20ms)

- **Option "DualCount" "***count***"**

  Number of skipped "dual touch error". Reports are sent approx.  every 20ms. This option is only available for "ZPress" and  "ZPress Exit" modes.

  *Range:* "0" - "31"

  *Default:* "2" (2 skipped messages = 40ms)

## SEE ALSO

XFree86(1), [XF86Config-4(5x)](/XF86Config-4/5x.md), xf86config(1), [Xserver(1)](/Xserver/1.md), [X(7x)](/X/7x.md).