Reference

array-info(1)

check the status of a HP (Compaq) SmartArray controller

NAME

array-info - check the status of a HP (Compaq) SmartArray controller

SYNOPSIS

FCarray-info -d array_device_pathF[0] [-a|-l|-A|-c|-s|-L|-h]

DESCRIPTION

Array-info is a command line tool to retrieve informations and logical drives status from several RAID controllers (currently HP Compaq IDA and CISS and MD). It displays informations about the firmware version, Rom revision, number of physical and logical drives on the controller, aswell as the fault tolerance, size, number of physical disks and status for each logical drive.

OPTIONS

FC--device | -dF[0]

Path to array device, e.g. /dev/ida/c0d0 or /dev/cciss/c0d1

FC--all-drives | -aF[0]

Show informations about all drives

FC--logical drive | -lF[0]

Show informations about selected logical drive

FC--show-ctrl | -cF[0]

Show informations about controller

FC--show-logical | -LF[0]

Show informations about logical drives

FC--show-physical | -pF[0]

Show physical device informations

FC--show-status | -sF[0]

Show status of logical drives

FC--show-all | -AF[0]

Show all informations

FC--version | -VF[0]

Show version

FC-hF[0]

Show help about options

COPYRIGHT

This manual page was written by Raphaël Pinson <<[email protected][0]>>. Permission is granted to copy, distribute and/or modify this document under the terms of the GNU General Public License, Version 2 or any later version published by the Free Software Foundation.