name: "SNMP::Info::Layer3::Scalance"
section: "3pm"
platform: "linux"
package: "libsnmp-info-perl"
version: "3.972002-1"
release: "Debian 13 (Trixie)"
platforms: ["linux"]
url: "https://new.carta.tech/SNMP::Info::Layer3::Scalance"
---

# SNMP::Info::Layer3::Scalance(3pm)

SNMP Interface to Siemens Scalance Switches

## NAME

SNMP::Info::Layer3::Scalance - SNMP Interface to Siemens Scalance Switches

## AUTHOR

Christoph Handel

## SYNOPSIS

```
 # Let SNMP::Info determine the correct subclass for you.
 my $scalance = new SNMP::Info(
                          AutoSpecify => 1,
                          Debug       => 1,
                          DestHost    => 'myswitch',
                          Community   => 'public',
                          Version     => 2
                        )
    or die "Can't connect to DestHost.\n";
 my $class      = $scalance->class();
 print "SNMP::Info determined this device to fall under subclass : $class\n";
```

## DESCRIPTION

Provides abstraction to the configuration information obtainable from a Siemens Scalance Switch via SNMP.

Tested only with scalance xr524

### Inherited Classes

- SNMP::Info::Layer3

  - SNMP::Info::MAU

  ### Required MIBs

- *AUTOMATION-SMI*

  - *AUTOMATION-SYSTEM-MIB*

  - *AUTOMATION-TC*

  - *SIEMENS-SMI*

  - *SN-MSPS-SCX-MIB*

  \<https://support.industry.siemens.com/cs/document/22015045/private-mibs%3A-scalance-x-scalance-w-and-snmp-opc-profile?dti=0&lc=en-DE\>

\<https://support.industry.siemens.com/cs/document/67637278/automationmib-now-available-for-download-in-version-v02-00-00-02-?dti=0&lc=en-TN\>

## Change Log

## GLOBALS

These are methods that return scalar value from SNMP

- $scalance-\>**layers()**

  Overwrite snmp value, we support 1-3

- $scalance-\>**os()**

  Returns scalance

- $scalance-\>**vendor()**

  Returns siemens

- $scalance-\>**model()**

  extract a meaningful name from description

- $scalance-\>**mac()**

  use the dot1dBaseBridgeAddress

- $scalance-\>**os\_ver()**

  clean up os\_version string

- $scalance-\>**i\_description()**

  siemens returns a description including firmware, switch serial, etc clean it up. Try to use anything past VLAN or Port. And if this fails  past the last comma

- $scalance-\>**lldp\_ip()**

  simatic does not implement lldpRemManAddrIfSubtype but remote system names are available try to resolve them via DNS and use that

### Globals imported from SNMP::Info::Layer3

See documentation in "GLOBALS" in SNMP::Info::Layer3 for details.

### Globals imported from SNMP::Info::MAU

See documentation in "GLOBALS" in SNMP::Info::MAU for details.

## TABLE METHODS

These are methods that return tables of information in the form of a reference to a hash.

### Overrides

- $scalance-\>**lldp\_ip()**

  Returns reference to hash of ports to remote ips.

  simatic does not implement lldpRemManAddrIfSubtype but remote system names are available try to resolve them via DNS and use that.

### Table Methods imported from SNMP::Info::Layer3

See documentation in "TABLE METHODS" in SNMP::Info::Layer3 for details.

### Table Methods imported from SNMP::Info::MAU